INFINITY®
SIGNAL CONDITIONERS
RS-485 CONFIGURABLE WITH RS485 OUTPUT
PROCESS
VOLTAGE OR CURRENT DRX-PR
The DRX-PR signal
conditioner accepts process signal inputs within the spans of 400mV, 1,
2, 5, 10V, and 20mA. Excitation of 10 or 14Vdc @ 20mA max. is available
for use with the input device. Accuracy is 0.1% with 13 bit resolution
and computer scalable via RS-485 using the DRX-CONFIG software package.
|
PROCESS
VOLTAGE OR CURRENT DRX-PR |
$275.00
|
STRAIN
GAGE/BRIDGE OR MILLIVOLT
DRX-ST The DRX-ST signal conditioner accepts strain gage/bridge or millivolt
inputs with ratiometric or absolute measurement. 10V excitation is standard.
Input spans of 30 or 100mV full scale. Accuracy is 0.1% with 13 bit resolution
and computer scalable via RS-485 using the DRX-CONFIG software package.
|
STRAIN
GAGE/BRIDGE OR MILLIVOLT |
$300.00
|
THERMOCOUPLE INPUT
DRX-TC
The DRX-TC signal conditioner accepts thermocouple types J, K, T, R, S,
B, N and J-DIN. The analog output is configurable for 0 to 10Vdc, 0 to
20mA or 4 to 20mA. Input and output configuration is via RS-485 using
the DRN-CONFIG software package. The DRX series features 3-way isolation
to 1800V peak, ▒1░C accuracy and resolution to 0.3░C above -200░C.
|
THERMOCOUPLE
INPUT |
$250.00
|
RTD
INPUT
DRX-RTD The DRX-RTD
signal conditioner accepts 100, 500 or 1000 ohm RTDs with alpha of 0.00385
or 0.00392. Input and output configuration is via RS-485 using the DRX-CONFIG
software package. The DRX series features 3-way isolation to 1800V peak,
▒1░C accuracy and resolution to 0.1░C.
AC
VOLTAGE INPUT
DRX-ACV The DRX-ACV
signal conditioner accepts AC voltage input ranges of 400mV, 4V, 40V and
400V. Accuracy is 0.2% with 13 bit resolution and computer scalable via
RS-485 using the DRX-CONFIG software package. The DRX series features
3-way isolation to 1800V peak.
AC
CURRENT INPUT
DRX-ACC The DRX-ACC
signal conditioner accepts AC current input ranges of 10, 100mA, 1A or
5A. Accuracy is 0.2% with 13 bit resolution and computer scalable via
RS-485 using the DRX-CONFIG software package. The ôDRX series features
3-way isolation to 1800V peak.
FREQUENCY/PULSE
INPUT
DRX-FP The DRX-FP
signal conditioner accepts pulse inputs from NPN/PNP open collector, TTL/CMOS,
magnetic and NAMUR proximity sensor outputs. Excitation of 5, 8.2 or 12.5Vdc
@ 25mA is available for the transducer. Frequency (0.2-50kHz) or Totalize/Reset
is standard. The Reset input can be reconfigured as a second input to
support A-B or Quadrature Totalize modes.
ACCESSORIES
DRN-PS-750
|
Power
supply, 24Vdc @750 mA output, 115 Vac input |
$130.00
|
DRN-PS-1000
|
Power
supply, 24Vdc @1 A output, 95-240 Vac input |
$150.00
|
CAT-285
|
Bi-directional
RS-232/RS-485 converter for DRX |
$148.00
|
DRX-CONFIG-9
|
Setup
software with 9-pin interconnection cable |
$100.00
|
DRX-CONFIG-25
|
Setup
software with 25-pin interconnection cable |
$100.00
|
INFINITY®
SIGNAL CONDITIONERS
RS-232
CONFIGURABLE WITH ANALOG OUTPUT
PROCESS
VOLTAGE OR CURRENT DRX-PR
The DRN-PR-C signal
conditioner accepts process signal inputs within the spans of 400mV, 1,
2, 5, 10V, and 20mA. Excitation of 10 or 14Vdc @ 20mA max. is available
for use with the input device. Accuracy is 0.1% with 13 bit resolution
and computer scalable via RS-232 using the DRN-CONFIG software package.
|
PROCESS
VOLTAGE OR CURRENT DRX-PR |
$325.00
|
STRAIN
GAGE/BRIDGE OR MILLIVOLT
The DRN-ST-C signal
conditioner accepts strain gage/bridge or millivolt inputs with ratiometric
or absolute measurement. 10V excitation is standard. Input spans of 30
or 100mV full scale. Accuracy is 0.1% with 13 bit resolution and computer
scalable via RS-232 using the DRN-CONFIG software package.
|
STRAIN
GAGE/BRIDGE OR MILLIVOLT |
$345.00
|
THERMOCOUPLE
INPUT
The DRN-TC-C signal
conditioner accepts thermocouple types J. K, T, E, R, S, B, N and J-DIN.
The analog output is configurable for 0 to 10Vdc, 0 to 20mA or 4 to 20mA.
Input and output configuration is via RS-232 using the DRN-CONFIG software
package. The DRN series features 3-way isolation to 1800V peak, ▒1░C accuracy
and resolution to 0.3░C above -200░C.
|
THERMOCOUPLE
INPUT |
$325.00
|
RTD
INPUT
The DRN-RTD-C signal
conditioner accepts 100, 500 or 1000 ohm RTDs with alpha of 0.00385 or
0.00392. Input and output configuration is via RS-232 using the DRN-CONFIG
software package. The DRN series features 3-way isolation to 1800V peak,
▒1░C accuracy and resolution to 0.1░C.
AC
VOLTAGE INPUT
The DRN-ACV-C signal
conditioner accepts AC voltage input ranges of 400mV, 4V, 40V and 400V.
Accuracy is 0.2% with 13 bit resolution and computer scalable via RS-232
using the DRN-CONFIG software package. The DRN series features 3-way isolation
to 1800V peak.
AC
CURRENT INPUT
The DRN-ACC-C signal conditioner accepts AC current input ranges of 10,
100mA, 1A or 5A. Accuracy is 0.2% with 13 bit resolution and computer
scalable via RS-232 using the DRN-CONFIG software package. The DRN series
features 3-way isolation to 1800V peak.
FREQUENCY/PULSE
INPUT
The DRN-FP-C signal
conditioner accepts pulse inputs from NPN/PNP open collector, TTL/CMOS,
magnetic and NAMUR proximity sensor outputs. Excitation of 5, 8.2 or 12.5Vdc
@ 25mA is available for the transducer. Frequency (0.2-50kHz) or Totalize/Reset
is standard. The Reset input can be reconfigured as a second input to
support A-B or Quadrature Totalize modes.
ACCESSORIES
DRN-PS-750
|
Power
supply, 24Vdc @750 mA output, 115 Vac input |
$130.00
|
DRN-PS-1000
|
Power
supply, 24Vdc @1 A output, 95-240 Vac input |
$150.00
|
DRN-CONFIG-9
|
Setup
software with 9-pin interconnection cable |
$100.00
|
DRN-CONFIG-25
|
Setup
software with 25-pin interconnection cable |
$100.00
|
|